BC VRI canopy-only scenario =========================== Purpose ------- ``scripts/vri_canopy_scenario.py`` tests whether the measured FFS canopy reduction alone changes fire behaviour on an open BC VRI stand. Setup ----- - 100 m grid over the MKRF VRI AOI; - fixed C2 fuel type; - control closure 55–70%; - treated closure −22.9%; - flat terrain and fixed FFMC 90, BUI 60, wind 20 km/h, 270°; - 120-minute run. Result ------ Control and treated both burn 228.0 ha with a 7,000 m perimeter and 16.149 m/min head ROS. The canopy-only treatment has no effect in this C2 case. That is a negative result for crown closure as the treatment mechanism, not a validation of a treatment. Limits ------ - One AOI, one fuel type, one weather case. - No surface-fuel or fuel-type conversion. - BC CRI treatment locations are Access Only. - No operational claim. Report: ``notes/reports/vri-canopy-scenario.md``.