Containment boundary and validation protocol

Containment contract

The observed-fire runner accepts an optional boolean containment mask:

  • False cells are normal fuel.

  • True cells are contained/non-burnable, such as a firebreak or suppression line.

  • The default is None, preserving free-burn behavior.

  • The mask must match the grid and leave burnable cells.

The mask is a management scenario input, not a fitted calibration parameter.

Validation protocol

P176 showed that the model fills the connected burnable basin:

  • median simulated area / basin: 0.995;

  • median observed area / basin: 0.130;

  • 8 of 12 simulations fill at least 95% of the basin.

Therefore:

  • use large/free-burn fires for ROS and event skill;

  • use small/suppressed fires only for potential-growth or containment scenarios;

  • do not tune ROS to suppressed small fires.

P164.3 calibration remains paused until the protocol is applied to free-burn evidence.