BC VRI canopy-only scenario

Purpose

scripts/vri_canopy_scenario.py tests whether the measured FFS canopy reduction alone changes fire behaviour on an open BC VRI stand.

Setup

  • 100 m grid over the MKRF VRI AOI;

  • fixed C2 fuel type;

  • control closure 55–70%;

  • treated closure −22.9%;

  • flat terrain and fixed FFMC 90, BUI 60, wind 20 km/h, 270°;

  • 120-minute run.

Result

Control and treated both burn 228.0 ha with a 7,000 m perimeter and 16.149 m/min head ROS.

The canopy-only treatment has no effect in this C2 case. That is a negative result for crown closure as the treatment mechanism, not a validation of a treatment.

Limits

  • One AOI, one fuel type, one weather case.

  • No surface-fuel or fuel-type conversion.

  • BC CRI treatment locations are Access Only.

  • No operational claim.

Report: notes/reports/vri-canopy-scenario.md.