BC VRI canopy-only scenario
Purpose
scripts/vri_canopy_scenario.py tests whether the measured FFS canopy reduction alone changes
fire behaviour on an open BC VRI stand.
Setup
100 m grid over the MKRF VRI AOI;
fixed C2 fuel type;
control closure 55–70%;
treated closure −22.9%;
flat terrain and fixed FFMC 90, BUI 60, wind 20 km/h, 270°;
120-minute run.
Result
Control and treated both burn 228.0 ha with a 7,000 m perimeter and 16.149 m/min head ROS.
The canopy-only treatment has no effect in this C2 case. That is a negative result for crown closure as the treatment mechanism, not a validation of a treatment.
Limits
One AOI, one fuel type, one weather case.
No surface-fuel or fuel-type conversion.
BC CRI treatment locations are Access Only.
No operational claim.
Report: notes/reports/vri-canopy-scenario.md.