Crown fire
Purpose
The crown-fire layer adds the vertical dimension to the FBP surface fire: does the surface fire ignite the canopy, how much of the canopy burns, and how does the crown fuel change the head fire intensity?
The initiation threshold is Van Wagner’s critical surface intensity. The crown fraction burned and the C6 crown rate of spread are the Canadian FBP formulations. A separate Van Wagner active-crown threshold is available when a canopy bulk density is supplied.
Initiation
Van Wagner’s critical surface intensity is:
CSI = 0.001 × CBH^1.5 × (460 + 25.9 × FMC)^1.5
where CBH is the crown base height in metres and FMC is the foliar moisture content in
percent. The critical surface rate of spread is CSI / (300 × SFC).
The FBP crown fraction burned is:
CFB = 1 - exp(-0.23 × (surface ROS - critical ROS)) when surface ROS > critical ROS
CFB = 0 otherwise
A fuel type with no crown fuel load (D-1, S-1…S-3, O-1) has CFB = 0.
C6 crown fire
C6 uses a separate crown rate of spread:
FME = ((1.5 - 0.00275 × FMC)^4) / (460 + 25.9 × FMC) × 1000
RSC = 60 × (1 - exp(-0.0497 × ISI)) × FME / 0.778
The head fire rate of spread is the surface ROS plus the crown fraction of the difference between the crown ROS and the surface ROS.
Classification
The fire description is:
SSurface fire,
CFB < 0.1.IIntermittent or passive crown fire,
0.1 <= CFB < 0.9.CActive crown fire,
CFB >= 0.9.
When a canopy bulk density is supplied, the Van Wagner active-crown threshold is also
reported: the head fire ROS reaches 3 / CBD m/min.
Behaviour classes
P163.1 turns the FBP outputs into four explicit classes:
ground— low-intensity/smoldering proxy when flame length is below 0.5 m and CFB is below 0.1;surface— flaming surface fire with CFB below 0.1 and flame length at least 0.5 m;passive_crown— CFB from 0.1 to below 0.9;active_crown— CFB at or above 0.9.
The class is recorded as fire_behaviour on the fire event. surface->passive_crown and
passive_crown->active_crown are explicit transitions. The ground class is a proxy for a
low-intensity surface state; WS4 does not yet model duff/peat combustion or smoldering spread.
Validation
The implementation is validated against the cffdrs R package:
all 17 fuel types at FFMC 90, BUI 60, 10 km/h wind, flat ground;
a 320-point grid across C2, C3, C7, M1, and S1;
three C6 cases, including two active crown fires.
Crown fraction burned and head fire rate of spread match within 0.02; head fire intensity matches within 1.0 kW/m. The fire description matches on every case.
Example
python examples/fire_crown_demo.py
The demo prints:
fuel CFB FD surface ROS head ROS HFI kW/m flame m
C2 0.809 I 8.33 8.33 7845.4 4.80
C4 0.765 I 8.79 8.79 7039.7 4.56
M3 0.806 I 10.36 10.36 8444.5 4.96
C6 crown case: FFMC 95, BUI 80, WS 20 -> CFB 0.962, C, HFI 45409.1 kW/m
Limits
Flat ground only. Slope adjustment is P156.4.
No spotting or ember transport.
No growth geometry; the result is a point/weather behaviour, not a perimeter.
The FMC is derived from latitude, longitude, elevation, and Julian day, or supplied explicitly.
The active-crown threshold is optional because it needs a canopy bulk density; the FBP
CFBclass is always reported.The VRI-to-FBP fuel-type mapping is P156.9.